Sample rate conversion for DUNE FD VD TPC ADCwire-cell Describes the different sample rates of the DUNE FD VD top and bottom detector electronics, 512 ns at 14 bits versus 500 ns, and the resulting problems for readout time, cluster matching, field response and configuration. It proposes sample rate conversion by rational interpolation, using integral upsampling and downsampling in the frequency domain, and discusses choosing the number of samples so the interpolation stays integral. It also notes that the official VD sampling numbers still need a definitive public reference.sample rate conversion resampling dune vd adc interpolation fft nyquist