Supernova Neutrino Burst Data Streaming from DUNE FD DAQ
Getting good enough pointing information out fast enough
Asks whether a minimal, supernova-neutrino-enriched data stream can be pulled from the DUNE far-detector DAQ fast enough to support prompt pointing reconstruction. The proposed chunk-stream readout fetches 200 microsecond windows around selected trigger activities. The study targets efficiency and purity, data rate and latency, and pointing resolution, with a pointing latency goal of 3 minutes.