DUNE Resamplingtalks Explains how DUNE PD and FD TPC detectors use 500 ns and 512 ns sampling periods, creating mental, configuration and algorithmic complexity for offline software. It motivates resampling ADC waveforms …
Configuring WCT for running in art/LArSoft for DUNEtalks Discusses how DUNE’s move from 12 to 14 bit ADC resolution affects Wire-Cell Toolkit configuration, and surveys the DAQ-related parameters from drift and signal through noise and digitizer settings. …
LMN Resampling for DUNE TPC Raw Datatalks Proposes mitigating the mix of 500 and 512 ns ADC sampling in DUNE FD TPCs by upsampling waveforms from 512 to 500 ns inside the first offline processing stage. It surveys the FD sampling options and …
Sample rate conversion for DUNE FD VD TPC ADCtalks Describes the different sample rates of the DUNE FD VD top and bottom detector electronics, 512 ns at 14 bits versus 500 ns, and the resulting problems for readout time, cluster matching, field …