From kettell@bnl.gov Wed Aug 20 14:38:37 2003
Date: Wed, 20 Aug 2003 09:45:49 -0400
From: Steve Kettell <kettell@bnl.gov>
To: Jingliang Hu <hujl@sitka.triumf.ca>
Cc: "Frank, James  S" <frank@bnl.gov>, 'Akira Konaka ' <konaka@triumf.ca>,
     ''Takeshi Komatsubara ' ' <koma@post.kek.jp>,
     Steve Kettell <kettell@bnl.gov>, Shaomin Chen <chensm@triumf.ca>
Subject: RE: beam analysis review

Hi Jingliang,

On Tue, 19 Aug 2003, Jingliang Hu wrote:
>         02 (1/3)      98 (1/3)    98 (2/3)
>  K-K     80/3          53/3        114/2        
>  K-pi   2865/224      1260/20     2535/22
> 
> for the K-K entering, i think they are statistically consistent. for 
> K-pi entering, the combined rejection of b4trs*b4ccd is about 12.80,
> which is much lower than 98. there could be two reasons- 
>    1. the rejection of b4ccd is lower than b4td because i set a 
>       pretty high energy threshold for B4CCD cut. even i used a 
>       refined B4CCD cut (after clustering) this part is still
>       tough for the pion passing through the edge of a B4 counter-
>       the reason for this is- to ensure that the quality of double
>       pulse fit is good, i have to set a cut on both chi2 and 2nd
>       pulse area.

What do you do if the pion passes through the edge and is found in one B4
counter by B4CCD and the adjacent B4 counter by B4TBM? Do you cluster
these two together, since they have the same time?

> > 3) In Table 1 of your original note, you showed that the resolution on
> > B4TBM is about the same as 1998 (presumably some cancellation of
> > degradation due to less B4 light output and improvement from CCD based
> > timing of B4 and tk?) What is B4TBM? B4 relative to what? How is B4STR
> > resolution compared to 1998? Do you include 2nd pulses found by B4CCD in
> > B4STR? Do you want to cluster B4CCD? or simply use a low threshold to get
> > pions going through the edge of B4?
> 
> The B4TBM there is actually B4TBM_atc, relative to B4STR_atc (which is the 
> time of a B4 hit closest to TK time). the resolutions:
>         B4STR(ns)     B4STR_ATC
>   02     0.63           0.62
>   98     0.69
> But, the consistency between TK and B4STR looks to be much better this
> year (02: 0.38ns, 98: 0.83ns).

OK. We know that tk is much better in 2002 due to the target CCD's. Can
you compare B4TBM and B4STR to Ck (I assume that Ck was pretty good in
1998 as well as in 2002). This is to see how the B4 timing compares to
1998. (B4TBM by itself is not a fair comparison, since you are timing B4
against itself.)

> > The B4CCD clustering is already done- needs a fine tuning of the 
> threshold.

(see my question above about clustering B4CCD with B4TBM) But I was trying
to understand if a pulse found by the B4 CCD's as a second pulse would be
included in B4TBM or B4STR? In other words, can a candidate pnn event have
a B4 hit that is a few nanoseconds before the actual kaon?

	Steve