From hujl@sitka.triumf.ca Wed Aug 20 14:38:49 2003
Date: Tue, 19 Aug 2003 14:53:11 -0700
From: Jingliang Hu <hujl@sitka.triumf.ca>
To: Steve Kettell <kettell@bnl.gov>
Cc: "Frank, James  S" <frank@bnl.gov>, 'Akira Konaka ' <konaka@triumf.ca>,
     ''Takeshi Komatsubara ' ' <koma@post.kek.jp>,
     ''Shaomin Chen ' ' <chensm@triumf.ca>
Subject: RE: beam analysis review

Hi, Steve,

thanks for the questions.

> Jingliang, A couple of new questions occur to me: 
> 1) Can you define the categories I-VIII on p7 (Q5 from Steve)?
  
sure, will add the definition in a refined bm_qanda.ps

> 2) Have you made any further understanding of why B4TRS*B4CCD has so much
> less rejection in your 2-beam normalization study?

it is a good question. before i give an explanation, i would like to
list the rejection in comparison with 98 data

        02 (1/3)      98 (1/3)    98 (2/3)
 K-K     80/3          53/3        114/2        
 K-pi   2865/224      1260/20     2535/22

for the K-K entering, i think they are statistically consistent. for 
K-pi entering, the combined rejection of b4trs*b4ccd is about 12.80,
which is much lower than 98. there could be two reasons- 
   1. the rejection of b4ccd is lower than b4td because i set a 
      pretty high energy threshold for B4CCD cut. even i used a 
      refined B4CCD cut (after clustering) this part is still
      tough for the pion passing through the edge of a B4 counter-
      the reason for this is- to ensure that the quality of double
      pulse fit is good, i have to set a cut on both chi2 and 2nd
      pulse area.
   2. we had a PBNRS cut (lead glass) for 98 data analysis, which
      had a rejection of 2-3.
 
> 3) In Table 1 of your original note, you showed that the resolution on
> B4TBM is about the same as 1998 (presumably some cancellation of
> degradation due to less B4 light output and improvement from CCD based
> timing of B4 and tk?) What is B4TBM? B4 relative to what? How is B4STR
> resolution compared to 1998? Do you include 2nd pulses found by B4CCD in
> B4STR? Do you want to cluster B4CCD? or simply use a low threshold to get
> pions going through the edge of B4?

The B4TBM there is actually B4TBM_atc, relative to B4STR_atc (which is the 
time of a B4 hit closest to TK time). the resolutions:
        B4STR(ns)     B4STR_ATC
  02     0.63           0.62
  98     0.69
But, the consistency between TK and B4STR looks to be much better this
year (02: 0.38ns, 98: 0.83ns).

The B4CCD clustering is already done- needs a fine tuning of the
threshold.

> 4) on p10 (Q2 from VRVS) you show B4E for kaons peaked at 1.0. What do
> pions (piscats) look like? Is the peak at 0.1 really `accidentals' as you
> claim? or might it be `noise'?

the pion peaks at around half of the kaon peak. 

sorry, 'accidentals' is a wrong naming, should be 'noise'.

thanks,

jingliang