From kettell@bnl.gov Thu Jun 19 15:00:28 2003
Date: Thu, 19 Jun 2003 11:07:41 -0400
From: Steve Kettell <kettell@bnl.gov>
To: Jingliang Hu <hujl@sitka.triumf.ca>
Cc: Jim Frank <frank@bnl.gov>, Steve Kettell <kettell@bnl.gov>,
     Akira Konaka <konaka@Triumf.CA>
Subject: Re: TN for beam analysis review.

Hi Jingliang,

On Tue, 10 Jun 2003, Jingliang Hu wrote:
> A note for the beam analysis is now available at 
>    http://sitka.triumf.ca/~hujl/e949bm/tn_bm.ps

Were you going to correct Table 4 in this document?

I am now working on our writeup of the beam review and I am puzzled.
Do you know where I can find the 1998 versions of your figures 18-21? Are
your 1998 numbers (in parenteses) for the 1/3 or the full sample? I have
been assuming that they were also for the 1/3 sample....

If I try to calculate the 2-beam backgrounds in 1998 and 2002 I get:

year  K-K norm  K-K rej  K-K bck  K-pi norm  K-pi rej  K-pi bck Tot Bck
----  --------  -------  -------  ---------  --------  -------- -------
2002   0.053	116.2	 4.6e-4	  0.147	     14553.0   1.0e-5	4.7e-4	
1998   0.058	113.7	 5.1e-4	  0.016	      1426.9   1.1e-5	5.2e-4

So the 2002 2-beam background appears to be smaller than 1998!!

If I multiplty both by x3 I get:

2002 = 0.00141 (not quite the 0.00133 that you get in Table 5)
1998 = 0.00156 (drastically different than the .0004 that you quote!)

	Steve