From: Jingliang Hu [mailto:hujl@sitka.triumf.ca]
Sent: Monday, June 16, 2003 5:28 PM
To: Frank, James S
Cc: Jingliang Hu
Subject: questions and comments from VRVS beam study review.


Hi, Jim,

below is a list of all questions and comments i got
from some referees. These questions and comments will
be put on my website together with the answers.

thanks,

jingliang

++++++++
	Questions or Comments for BM studies

-- Jim

   1.
   If both TDC and CCD hits exist, you use the
   time from the TDC.  What 'average' do you mean
   for the energy?  Do you mean the average of
   the ADC and the CCD energy?  Is the CCD energy
   from the pulse-finding, or does it come from
   the fitting?

   2.
   I'm finding that the pulsate algorithm,
   applied to target pulses gets energies
   that are too high.  Do you see similar
   in the B4, and if so, do you do any 
   correction for this?

   3.
   How do you define when a particle
   goes through the middle or the edge?
   Is it just if it hits an adjacent
   counter?  If so, I'd expect significantly
   more hits on the 'edge' than in the middle,
   which isn't indicated in Fig 8.

   4.
   The TGTCON cut is set at 3.75ns.  I think
   the cut should be made as a function of ek_tg.
   For example, the resolution for 0.5 MeV kaon
   fibers is very much worse than for 5 MeV fibers.
   Though you're losing little acceptance by this
   cut, maybe there's a more efficient way to
   make the cut.

-- Takeshi

    1. page 2 (and Plot 102 on Fig 3) 
    What is the unit of the X-axis of the plot (and
    of "0.1" and "0.135")? Is it MeV ?? 

    2. page 5
    I was not able to understand the "reliability
    function" in Fig 4. The reliability is checked
    when only a CCD hit exists; how can we calculate
    the reliability of the hit from "B4 ADC (calib.)" ?? 

    3. page 16
    - In pnn(1)-98 analysis, 
    the DELC "pathology" cuts set the limits of 3nsec,
    4nsec and 5nsec according to the categories. 
    In your case, you impose the cut at 5nsec for all
    of these ?? 

    - You use the information of b4str (from B4) and
    trs (from RS) for the calculation of kaon-time and
    pion-time in some cases, instead of using tk and tpi
    from target and setting a tighter cut.

    Did you check if the new kaon-time and pion-time
    could introduce a "correlation(?!)" to the beam cuts ?? 
    (We always worry about a correlation when a combined
    cut is newly developed...)

    4. page 19
    A comment: 
    In the Kpi2 based acceptance study, 
    the OPSVETO cuts are imposed at first, separately,  
    in order to removed the events when one of the photons 
    starts conversion within the target. 

    Such events cannot be removed by SETUP_ops
    in which large visible energy (but not the two clusters)
    in BV/BVL is required. 

    In the E787 1gamma study I had discovered that 
    the Kpi2 based acceptance study can be performed more
    reliably if we tag two photons from pi0 in BV/BVL using
    the clustering rotine (by Tamaki). See page 41 and page
    128-129 if you are interested in the technique.

-- Steve

    1.
    Bottom line: 1-beam is 6% higher than 1998 (for half
    the KB_L), but 2-beam is x3.3 higher, correct?

    Is the increased 2-beam from K-K or K-pi?

    2.
    Can I interpret Fig#20-21 to indicate that we have the
    same K-K rejection as 1998 and x10 more K-pi rejection?

    ...and we have the same number of K-K normalization
    events as 1998 and x9 more K-pi events? (even though 1998
    has x2 more KBL)

    ...doesn't this imply that K-K and K-pi are both about the
    same as 1998?

    3.
    In Fig#21 why do we have x2 more events (than 1998) in the
    skm3 setup? and after CPITRS we have equal numbers (but we
    have x10 more pi rejection (from Fig#20)

    4.
    What does a "big" cluster mean? >=3 counter? or >3 counters?
    Can you explain how this identifies 'accidentals'?

    5.
    "it is 'easy' to see from Fig#17 that more bkg is killed..."
    I hope that you will explain this, for those who do not find
    it easy.

    6.
    It seems that you have done well with B4 timing, given that
    we have less light than in 1998. I have a few questions
    however.

    First, why is the resolution on the fitted 2nd pulses (Fig#11)
    worse than 1998 (1.0ns -> 1.7ns)? We have CCD's instead of
    multiplexed TD's now - this should be better, no? We have less
    light (but the B4TBM resolution is now better 0.62 -> 0.58,
    right?) How much data comes from 2nd pulse fits?

    7.
    In Fig#3, why is the B4U and B4V resolution worse than B4UV?
    Have you made a position-based timing correction in the B4UV
    plot? or are these all uncorrected and we just have x2 more
    measurements?

    8.
    How do you get from 1.2ns in Fig#3 for B4UV to 0.7ns in B4TBM
    in Fig#5? How do you get from 0.60ns in Fig#5 to 0.58ns in
    Table#1 and Fig#7

-- Got during the VRVS review meeting

   1. page 5
   For analyzer ATC mode, how do the b4abm_atc, b4tbm_atc change
   if we use CCD time information instead of TDC time when both
   CCD and TDC are available?

   2. page 4
   extend the region scale from 1.0 to 2.0 for plot 102 in Fig. 3
   to check where is the energy peak for the normal hits.

   3. page 12
   Replot Fig. 11- for more specific cases:
     * 2nd pulse is pion, hit the middle;
     * 2nd pulse is pion, hit the edge;
     * 2nd pulse is kaon, hit the middle;
     * 2nd pulse is kaon, hit the edge
   It is expected to figure out why the time resolution for CCD pulse
   fitting is worse than 98 TD.

   Clustering method needs to be used in a refined B4CCD cut.
    
   4. page 11
   How much rejection do we gain when UPVTRS/RVTRS cuts are introduced
   in the backgrounds study?

   5. comments
   tag the all B4 related variables used in the note with _atc if
   those variables are measured in ATC mode.

   6. page 16
   list the change in Rej./Acc for all DELC categories when the
   modification of (tpi-tk) is made.

   7. page 18
   cut position for B4EKZ should be retuned.

   8. page 19
   cut position for OPSVETO needs retuning

   9. page 22
   To understand why the rejections for (CKTRS*CKTAIL) and
   (CPITRS*CPITAIL) change much in 1- and 2- beam studies
   compared to 98 data.