From kettell@bnl.gov Thu Jun 19 14:58:47 2003
Date: Thu, 12 Jun 2003 10:54:44 -0400
From: Steve Kettell <kettell@bnl.gov>
To: Jingliang Hu <hujl@sitka.triumf.ca>
Cc: Takeshi Komatsubara <koma@post.kek.jp>, Jim Frank <frank@bnl.gov>,
     David Jaffe <djaffe@bnl.gov>, Tetsuro Sekiguchi <sekiguti@post.kek.jp>,
     Steve Kettell <kettell@bnl.gov>, Tamaki Yoshioka <tyosioka@post.kek.jp>
Subject: Re: TN for beam analysis review.

Hi Jingliang,

  Bottom line: 1-beam is 6% higher than 1998 (for half the KB_L), but
2-beam is x3.3 higher, correct?

  Is the increased 2-beam from K-K or K-pi?

  Can I interpret Fig#20-21 to indicate that we have the same K-K
rejection as 1998 and x10 more K-pi rejection?

...and we have the same number of K-K normalization events as 1998 and x9
more K-pi events? (even though 1998 has x2 more KBL)

...doesn't this imply that K-K and K-pi are both about the same as 1998?

In Fig#21 why do we have x2 more events (than 1998) in the skm3 setup? and
after CPITRS we have equal numbers (but we have x10 more pi rejection
(from Fig#20)


On Thu, 12 Jun 2003 koma@post.kek.jp wrote:
>  1. page 2 (and Plot 102 on Fig 3) 
> 
> 	What is the unit of the X-axis of the plot (and of "0.1" and "0.135") ?
>    	Is it MeV ?? 

What does a "big" cluster mean? >=3 counter? or >3 counters?
Can you explain how this identifies 'accidentals'?

>  3. page 16

"it is 'easy' to see from Fig#17 that more bkg is killed..." I hope that
you will explain this, for those who do not find it easy.


It seems that you have done well with B4 timing, given that we have less
light than in 1998. I have a few questions however.

First, why is the resolution on the fitted 2nd pulses (Fig#11) worse than
1998 (1.0ns -> 1.7ns)? We have CCD's instead of multiplexed TD's now -
this should be better, no? We have less light (but the B4TBM resolution is
now better 0.62 -> 0.58, right?) How much data comes from 2nd pulse fits?

In Fig#3, why is the B4U and B4V resolution worse than B4UV? Have you made
a position-based timing correction in the B4UV plot? or are these all
uncorrected and we just have x2 more measurements?

How do you get from 1.2ns in Fig#3 for B4UV to 0.7ns in B4TBM in Fig#5?
How do you get from 0.60ns in Fig#5 to 0.58ns in Table#1 and Fig#7

	Steve
?