From frank@bnl.gov Thu Jun 19 14:57:06 2003
Date: Wed, 11 Jun 2003 13:19:49 -0400
From: "Frank, James  S" <frank@bnl.gov>
To: "Frank, James  S" <frank@bnl.gov>, 'Jingliang Hu' <hujl@sitka.triumf.ca>
Cc: "Kettell, Steven" <kettell@bnl.gov>
Subject: RE: TN for beam analysis review.

    [ The following text is in the "iso-8859-1" character set. ]
    [ Your display is set for the "US-ASCII" character set.  ]
    [ Some characters may be displayed incorrectly. ]

Jingliang,

Another question, and a point of interest:

1) The TGTCON cut is set at 3.75ns.  I think
the cut should be made as a function of ek_tg.
For example, the resolution for 0.5 MeV kaon
fibers is very much worse than for 5 MeV fibers.
Though you're losing little acceptance by this
cut, maybe there's a more efficient way to
make the cut.

A quick look at some plots on bnlku36:
/home/scratch/frank/target/p2nt/ might illustrate
what I mean.  Using a few runs of km21 monitors,
tgtcon.ps shows the energy distribution of a
sample of ek_tg.  The top show those with
|tk_tg-tk|<2, the overlay 2<|tk_tg-tk|<4.
This shows a 'heavy' component of the time
outliers have energy<3 MeV.  The plot
tgtcon2.ps shows the tk_tg-tk for 3
different ek_tg bins: 10-30MeV, 3-10MeV,
and .lt.3 MeV.  Again, the correlation
is obvious.

2)  Since the target pulse fitting is (hopefully) working, 
I've been looking at the problem with the 2nd pulse energy
scale.  (I'm convinced the scale is wrong using the
pulsate algorithm).  I think that we will be able to
gain some acceptance if we 'correct' the epi_tg using
the fitted energy, rather than the 'pulsate' energy.
This will primarily be the epimax type of cuts, as
well as the opposite side pion cut.  Maybe 1% is
realizable.