From frank@bnl.gov Thu Jun 19 14:56:55 2003
Date: Wed, 11 Jun 2003 10:54:14 -0400
From: "Frank, James  S" <frank@bnl.gov>
To: 'Jingliang Hu' <hujl@sitka.triumf.ca>
Cc: "Kettell, Steven" <kettell@bnl.gov>
Subject: RE: TN for beam analysis review.

    [ The following text is in the "iso-8859-1" character set. ]
    [ Your display is set for the "US-ASCII" character set.  ]
    [ Some characters may be displayed incorrectly. ]

Jingliang-

A couple of questions on B4:

1) If both TDC and CCD hits exist, you use the
time from the TDC.  What 'average' do you mean
for the energy?  Do you mean the average of
the ADC and the CCD energy?  Is the CCD energy
from the pulse-finding, or does it come from
the fitting?

2) What happens when you have 2 ccd hits?
a) separated, or b) uses pulsate.

I'm finding that the pulsate algorithm,
applied to target pulses gets energies
that are too high.  Do you see similar
in the B4, and if so, do you do any 
correction for this?

3) How do you define when a particle
goes through the middle or the edge?
Is it just if it hits an adjacent
counter?  If so, I'd expect significantly
more hits on the 'edge' than in the middle,
which isn't indicated in Fig 8.

Jim