Turning power ON/OFF for RS TDC electronics
Turning power ON
- Turning CAMAC crates on is likely to cause temperature sensor trip.
That will cause loud ringing. To avoid that reset all temperature
sensors on Rack L17.
- Go to circuit breakers and turn on racks L2, L3, L6-L9,
L10, L12, L16-L18 . This list is to study RS TDC alone
with pulser trigger. For more complicated setups you may need
more racks turned on.
Circuit breakers A, B are
located on the second floor in the far corner near rack L1
. Circuit breaker C is located near the stairs.
- Also turn on racks with discriminatios. It will suppress
reflections from discriminators.
- If you plan to turn on FastBus and/or VME crates then go to the
crate and turn it on. So go to rack L10, L12 and do
it. Switches are located at the top of the rack. CAMAC crates
will come up automatically.
- Reset fake temperature sensors alarms on CAMAC racks you turned on,
They may accidentally tripped when you turned the circuit breakers on.
- If CAMAC crates have crate controllers check that they have
been initialized correctly: LED "BYP" should be on. If it is not
cycle the power in the crate.
- Turn on temperature sensors alarms on rack L17
- Go outside and turn Pump Power switch ON
(big box to the right)
Open chiller panel (big box to the left) and turn ON
unit service switch .
Compressor 1 service switch should be in position ON .
Turning power OFF
- Turn off temperature sensors alarms on rack L17
- Turn off VME/FastBus crates. The switches are located on the
top of the Rack. Some times switches are hard to see under the
cables, but they are there. Racks are: R9, R10, L10-L15
- Go to circuit breakers and turn off racks L2, L3, L6-L9,
L10, L12, L16-L18 . If you turned on more racks then shut
the as well. Circuit breakers A, B are located on the
second floor in the far corner near rack L1 . Circuit
breaker C is located near the stairs.
Note Leave switches A39, B61
in position ON
Hint You are likely to turn off everything, in this
case All switches except A39, B60, B61 should
be OFF
- Turn on temperature sensors alarms on rack L17
- Go outside and turn Pump Power switch OFF
(big box to the right)
Open chiller panel (big box to the left) and turn OFF
unit service switch .
Leave compressor 1 service switch in position ON .