Limitations of E-864


The design of E-864, especially the collimation and the ``geometry'' of the two analyzing magnets is such as to limit the applicability of the setup (to the topics for which the experiment was proposed). In particular, there are two directions into which it would be desirable to extend the capabilities. These are:

  1. The present setup is not sensitive to lifetimes much shorter than 50 ns. It would be very useful to redesign the front end of E-864 so that particles of more typically hyperonic lifetimes could be observed and measured.

  2. Because the present design was made for baryon studies, it has essentially no acceptance for particles with magnetic rigidity below ~ 1.5 GeV/c. there are a number of very interesting topics which could be addressed if acceptance for low rigidity particles could be added to E-864.