Summary on spare RS TDC channels August 30, 2001 Sasha Kushnirenko There are 144 channels associated with TS bank. Currently 14 are in use: 12 reference tubes + detector strobe + beam straobe. So there are 130 channels that potentially can be added to do timing in E949. There are 66 channels ready to be used. There are also 64 that are not currently working. 1. 16 channels in module 5 (15..31) Rack L17 - Crate 3 - Slot 19 - Lower 16 channels no cables are plugged in. 2. 4 channels in module 11 (12..15) Rack L17 - Crate 3 - Slot 09 - Upper 16 channels The cable already is plugged in, it runs from discriminator located at R7-C1-Slot 21. Just plug additional signals in that module. 3. 16 channels in module 11 (15..31) Rack L17 - Crate 3 - Slot 09 - Lower 16 channels no cables are plugged in. 4. 6 channels in module 17 (8..13) Rack L18 - Crate 3 - Slot 09 - Upper 16 channels The cable already is plugged in, it runs from discriminator located at R7-C3-Slot 21. Just plug additional signals in that module. 5. 16 channels in module 17 (15..32) Rack L17 - Crate 3 - Slot 19 - Lower 16 channels no cables are plugged in. 6. 8 channels in module 24 (0..7) Rack L17 - Crate 4 - Slot 04 - Upper 16 channels The cable already is plugged in, it runs from discriminator located at R5-C1-Slot 21. Just plug additional signals in that module. There are also 64 channels in 2 modules (18 & 30). Unfortunately they are not working at the moment. We will try to fix the situation, though we were not succesfull so far. Also we need at least one TDC as a spare for the RS TDC system as a whole. In software all 110 spare channels are associated with TS common block