EDEGRD

Energy deposited in the degrader.

EHODOS

Sum of B4 hodoscope energies

EHODOX(IX)

Energy loss in IX'th X hodoscope element

EHODOY(IY)

Energy loss in IY'th Y hodoscope element

NTARG

Number of target elements above threshold.

ETARGS

Total target energy loss.

ELOSTG

Target energy lost in dead material

ETARG(IROW,ICOL,ISEC)

Energy in the ISEC'th (1:4), IROW'th (1:14), ICOL'th (1:9) fiber bundle. The indices follow the same convention as the offline. Note that since the light guides are active, their energy is included here as well. ETARG values are actual energy losses - i.e. the saturation effect is NOT included.

EICTRS

Sum of energy loss in I counters

EICTR(I)

Energy loss in I'th (1:6) I counter.

EVETOS

Sum of energy loss in V counters

EVETO(I)

Energy loss in I'th (1:6) V counter.

ERANGE

total range stack energy.

ERANGS(IL,IA)

energy in the range stack element in the IL'th (1:21)layer and the IA'th (1:24) azimuthal segment. NOT corrected for saturation or scintillator attenuation.

ERANGM(IL,IA) and ERANGP(IL,IA)

apparent energy in the IL'th layer and IA'th phi segment -Z and +Z range stack element phototubes respectively. These energies include the density effect and scintillator attenuation.

ERNGSS(IL)

range stack energy summed over the IL'th layer.

EBLEAD

energy deposited in the barrel lead.

EBARS(IL,IA)

visible energy in the IL'th layer and IA'th azimuthal segment of the barrel array.

EBARM(IL,IA) and EBARP(IL,IA)

visible energy in the IL'th layer and the IA'th azimuthal segment of the barrel array for the -z and +z ends of the detector respectively. These arrays are corrected for attenuation etc. effects.

NCAP(IC)

number of modules in the IC'th ( 1==>-z , 2==> +z ) endcap with more than ETHREC of deposited visible energy

ECAP(IC)

total visible energy in the IC'th endcap array

ECAPSC(IP,IC)

visible energy in the IP'th segment of the IC'th endcap in MeV

ECAPPB(IC)

energy deposited in the lead of the IC'th endcap

ECAPBF(IC)

energy deposited in the BaF2 of the IC'th endcap (currently not implemented)

ELOSEC(IC)

lost energy in the IC'th endcap -- i.e., energy not lost in the scintillator or the lead.